Características del sistema de colchón Protekt Aire 7000:

  • Capacidad máxima de peso de 660 libras
  • Tiempos de ciclo alternos seleccionables de 10, 15, 20, 25 y 30 minutos con pantalla LED y modo estático para facilitar la transferencia del paciente.
  • El diseño del colchón de 18 celdas sobre celdas evita que el paciente se hunda en caso de un corte de energía.
  • El modo autofirme proporciona una configuración rápida y facilita el ingreso y egreso de la cama.
  • La cubierta superior acolchada de nailon es resistente a fluidos, antimicrobiana/antibacteriana, permeable al vapor y retardante al fuego.

Sistema de colchón Protekt® Aire 7000 con rotación lateral, baja pérdida de aire y presión y pulsación alternas

El sistema de colchón de aire Protekt® Aire 7000 es un sistema de reemplazo de colchón alternado que se utiliza para la prevención y el alivio de las úlceras por presión. El sistema de colchón de aire Protekt® Aire 7000 ofrece a los pacientes una superficie de apoyo cómoda y relajante mediante los principios establecidos de la terapia alternada, que puede prevenir el deterioro de la piel y facilitar la cicatrización. El sistema incluye una válvula de RCP giratoria de liberación rápida junto a la cabecera del colchón para casos de insuficiencia cardíaca.

La unidad de control del sistema de colchón de aire es una bomba con función de ajuste digital de presión, selección de modos y alarmas audiovisuales. El colchón de 18 celdas de aire ofrece un diseño único que mantiene las secciones inferiores de las celdas constantemente infladas, mientras que las secciones superiores se desinflan y alternan. Las tres celdas estáticas de la cabeza permanecen estáticas y proporcionan un soporte tipo almohada para una comodidad óptima. El colchón cuenta con una base de poliéster resistente con una cubierta acolchada de nailon permeable al vapor y recubierta de PU.

La función de giro lateral se logra mediante celdas de aire especialmente diseñadas para satisfacer las necesidades de enfermería. Esta función puede funcionar simultáneamente en modo alterno, pulsátil o estático. La orientación del paciente define la orientación del giro. El modo de giro único puede mantener el nivel de giro constante o alternar entre niveles de giro y no giro. El modo de giro completo alterna periódicamente entre giro a la izquierda, nivel horizontal, giro a la derecha y nivel horizontal.

Descripción general

Información

Protekt® Aire 7000 Lateral Rotation/Low Air Loss/Alternating Pressure and Pulsation Mattress System

The Protekt® Aire 7000 Air Mattress System is an alternating mattress replacement system used in the prevention and relief of pressure ulcers. The Protekt® Aire 7000 Air Mattress System offers patients a comfortable and relaxing support surface by using the established principles of alternating therapy, which can both prevent skin breakdown and enhance healing. The system includes a rapid-release twist CPR valve by the head section of the mattress for the event of cardiac distress.

The control unit of the air mattress system is a pump that features a digital pressure adjustment function, mode selections, and audiovisual alarms. The 18 air cells mattress unit provides a unique design that keeps the lower sections of air cells constantly inflated while alternating and deflating the upper sections. The 3 static head cells remain static and provide a “pillow” support for optimum comfort. The mattress has a heavy-duty polyester base sheet with a quilted, vapor-permeable nylon and PU-coated cover sheet.

The lateral rotation turning function is achieved by using specially designed lateral rotation turning air cells to achieve the nursing needs. The lateral rotation turning function can function with alternate, pulsate, or static mode at the same time. The patient’s orientation defines the orientation of turning. The single-turn mode can either maintain the turning level constantly or alternate between turning and non-turning levels. Full turn mode will alternate between left turn, horizontal level, right turn, and horizontal level periodically.

Documentos

Presupuesto

Dimensiones de la bomba (cm) 42,7 (largo) x 12,8 (ancho) x 23,3 (alto) Peso de la bomba (kg) 5.5 Dimensiones del colchón (cm)

200 (largo) x 90 (ancho) x 20 (alto)

200 (largo) x 107 (ancho) x 20 (alto)

30(H) con refuerzos

40(H)Nivel máximo de giro

50(H)Nivel máximo de giro con soporte

Peso del colchón (kg) 12 Tiempo de ciclo de alteración (minutos) 15/10/20 Tiempo de ciclo de pulsación (minutos) 15/10/20 Tiempo de ciclo de giro (minutos) 10-95 Tiempo de firmeza automático (minutos) 20 Rango de caudal de salida de la bomba (LPM) 9+9 Rango de presión (mmHg) 25-60 (±5) Voltaje de entrada CA 120 V 60 Hz Corriente de entrada 0,43 A máx. (@132 V~) Clasificación del fusible T1A 250 VCA Número de celdas de aire 18 Material celular Nailon-TPU Material de la cubierta Nailon-PU acolchado Material de la base Poliéster-PU Peso máximo (kg) 300

Garantía

Garantía

2 años no prorrateados

Envíos / Devoluciones

This unit is delivered via UPS or FedEx.

The following conditions apply:
  • This item has a 20% Restocking Fee.
  • You are responsible for the cost of return shipping.
  • The product must be new and unused and in the original packaging.
  • All accessories and items that were included in the box must be returned.
  • Items canceled after the product has already shipped will be considered a return.
  • Delivery and service fees are not refundable.
  • Custom-made by the manufacturer to suit your specific needs are non-returnable.
  • An RA (Return Authorization) from Top Mobility must be requested within 15 days of delivery.
  • The item must be shipped back to the address noted on the RA within 15 days.
  • Once approved, your refund, minus any restocking and freight fees, will be issued to your original form of payment.

  • If you have questions about this item please call a Top Mobility Customer Service Expert at 1-888-364-3813.
    Protekt Aire 7000 - Rotación lateral/Presión alterna/Baja pérdida de aire/Pulsación

    $2,995.00 USD