Protekt Aire 9900-36 - Sistema de colchón alternado con baja pérdida de aire

Sku: PAM-81090
Starting at: $3,350.00 USD
Ir directamente a la información del producto
1 de 3
Precio habitual $3,350.00
Los gastos de envío se calculan en la pantalla de pago.
  Lease to own   Pay as low as $/week
This product usually ships in 2-4 business days.

Pagos aceptados

Formas de pago
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Venmo
  • Visa

Características de Protekt Aire 9900:

  • Tecnología de verdadera baja pérdida de aire
  • Panel de control fácil de usar
  • Disponibles varios anchos
  • Capacidad de peso de hasta 1000 libras
Tecnología de vanguardia para la excelencia terapéutica

El sistema de colchón Protekt Aire 9900 con presión y pulsación alternas es una solución médica avanzada diseñada para satisfacer las necesidades de los pacientes que requieren una redistribución eficaz de la presión y un confort óptimo. Con una impresionante capacidad de flujo de aire de 1275 litros por minuto, este sistema de colchón ofrece una pérdida de aire realmente baja, garantizando un entorno terapéutico para los pacientes. La tecnología de microcontrolador de vanguardia desempeña un papel crucial en la monitorización de la velocidad del ventilador, lo que permite ajustes precisos de la presión.

El panel de control intuitivo, equipado con teclas de domo y una pantalla LED, ofrece una interfaz sencilla para que los profesionales sanitarios personalicen la redistribución de la presión según el peso del paciente. Los ciclos de presión alterna, con una duración de entre 5 y 30 minutos, ofrecen flexibilidad para que los profesionales sanitarios adapten la terapia a las necesidades individuales del paciente, lo que favorece la interacción con la piel y la comodidad general. El diseño del colchón de celdas sobre celdas garantiza la seguridad del paciente, evitando que se hunda en caso de un corte de energía, y la función automática de Fowler ajusta el flujo de aire cuando el paciente está en posición vertical.

Además, el Protekt Aire 9900 incluye funciones de seguridad adicionales, como alarmas sonoras y visuales para cortes de energía o baja presión. La memoria interna conserva la configuración actual durante cortes de energía y una llave de bloqueo impide la manipulación de la configuración del paciente. El sistema de colchón está equipado con una cubierta superior de nailon resistente a fluidos, antimicrobiana y antibacteriana que proporciona mayor comodidad e higiene. Con soportes de aire opcionales disponibles en varios anchos (42”, 48”, 54” y 60”) y una capacidad de peso de 454 kg, este sistema de colchón garantiza versatilidad y durabilidad. Con una garantía no prorrateada de 2 años, el sistema de colchón Protekt Aire 9900 es una solución confiable e integral para el cuidado del paciente.

Descripción general

Información

Cutting-Edge Technology for Therapeutic Excellence

The Protekt Aire 9900 Mattress System with Alternating Pressure and Pulsation is an advanced medical solution designed to address the needs of patients requiring effective pressure redistribution and optimal comfort. With an impressive airflow capacity of 1275 liters per minute, this mattress system offers 'true' low air loss, ensuring a therapeutic environment for patients. The state-of-the-art micro-controller technology plays a crucial role in monitoring blower speed, allowing for precise pressure settings.

The user-friendly control panel, equipped with dome keys and an LED display, offers a simple interface for clinicians to customize pressure redistribution based on patient weight. The alternating pressure cycles, ranging from 5 to 30 minutes, provide flexibility for healthcare professionals to tailor the therapy to individual patient needs, promoting skin surface interface and overall comfort. The cell-on-cell mattress design ensures patient safety by preventing bottoming out in the event of a power failure, and the automatic fowler feature adjusts air flow when the patient is in an upright position.

Furthermore, the Protekt Aire 9900 comes with additional safety features such as audio/visual alarms for power outage or low pressures. The internal memory retains current settings during power outages, and a lockout key prevents tampering with patient settings. The mattress system is equipped with a fluid-resistant, anti-microbial/anti-bacterial nylon top cover that adds a layer of comfort and hygiene. With optional air bolsters available in various widths (42”, 48”, 54”, and 60”), and a weight capacity of 1,000 lbs, this mattress system ensures versatility and durability. Backed by a 2-year non-prorated warranty, the Protekt Aire 9900 Mattress System is a reliable and comprehensive solution for patient care.

Documentos

Presupuesto

Dimensiones de la bomba (pulg.) 15,7 (ancho) x 6,8 (profundidad) x 10,8 (alto)
Peso de la bomba 14,3 libras.
Tiempo de ciclo alternativo (minutos) 5/10/15/20/25/30
Tiempo de ciclo de pulsación (minutos) 1 a 20
Tiempo de autofirme (minutos) 20
Caudal de salida de la bomba (LPM) 1000 (230 V) Nota: El caudal puede variar debido a la fluctuación del voltaje de entrada.
Rango de presión de salida de la bomba 20 a 46 (±5)
Voltaje de entrada CA 120 V/60 Hz
Capacidad de peso 350 a 1.000 libras.

Garantía

Garantía

2 años no prorrateados

Envíos / Devoluciones

This unit is delivered via UPS or FedEx.

The following conditions apply:
  • This item has a 20% Restocking Fee.
  • You are responsible for the cost of return shipping.
  • The product must be new and unused and in the original packaging.
  • All accessories and items that were included in the box must be returned.
  • Items canceled after the product has already shipped will be considered a return.
  • Delivery and service fees are not refundable.
  • Custom-made by the manufacturer to suit your specific needs are non-returnable.
  • An RA (Return Authorization) from Top Mobility must be requested within 15 days of delivery.
  • The item must be shipped back to the address noted on the RA within 15 days.
  • Once approved, your refund, minus any restocking and freight fees, will be issued to your original form of payment.

  • If you have questions about this item please call a Top Mobility Customer Service Expert at 1-888-364-3813.
    Protekt Aire 9900-36 - Sistema de colchón alternado con baja pérdida de aire

    $3,350.00 USD