Protekt Aire 9900 "True" Low Air Loss Bariatric Mattress System with Alternating Pressure and Pulsation

Sku: PAM-81090
Starting at: $3,350.00 USD
Skip to product information
1 of 3
Regular price $3,350.00
Shipping calculated at checkout.
  Lease to own   Pay as low as $/week
This product usually ships in 2-4 business days.

Accepted Payments

Payment methods
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Venmo
  • Visa

Protekt Aire 9900 "True" Low Air Loss Bariatric Mattress System with Alternating Pressure and Pulsation Features:

  • 1275 liters per minute of true low air loss.
  • Provides effective "true" low air loss with alternating pressure and pulsation.
  • State of the art micro-controller technology monitors blower speed to set pressures.
  • User-friendly control panel with dome keys, LED display for simple user interface. Displays patient comfort pressure level by weight.
  • Alternating pressure cycles of 5, 10, 15, 20, 25 & 30 minutes allows clinicians to customize pressure redistribution and skin surface interface.
  • Cell-on-cell mattress design prevents patient from bottoming out in case of power failure.
  • Automatic fowler (seat inflate) recognizes when the patient is in the upright position and increases air flow in the middle bladders by 20% to prevent bottoming out.
  • Audio/visual alarms in the event of power outage or low pressures. Internal memory always retains current settings during power outage.
  • Lock out key completely locks the control panel to eliminate tampering of the patient settings.
  • Nylon top cover is fluid resistant, anti-microbial/anti-bacterial and quilted for added comfort.
  • Optional air bolster helps mitigate accidental roll outs and are available on all sizes.
  • Available in 42”, 48”, 54” & 60” widths.
  • Weight Capacity: 1,000 lbs.

Overview

Info

Cutting-Edge Technology for Therapeutic Excellence

The Protekt Aire 9900 Mattress System with Alternating Pressure and Pulsation is an advanced medical solution designed to address the needs of patients requiring effective pressure redistribution and optimal comfort. With an impressive airflow capacity of 1275 liters per minute, this mattress system offers 'true' low air loss, ensuring a therapeutic environment for patients. The state-of-the-art micro-controller technology plays a crucial role in monitoring blower speed, allowing for precise pressure settings.

The user-friendly control panel, equipped with dome keys and an LED display, offers a simple interface for clinicians to customize pressure redistribution based on patient weight. The alternating pressure cycles, ranging from 5 to 30 minutes, provide flexibility for healthcare professionals to tailor the therapy to individual patient needs, promoting skin surface interface and overall comfort. The cell-on-cell mattress design ensures patient safety by preventing bottoming out in the event of a power failure, and the automatic fowler feature adjusts air flow when the patient is in an upright position.

Furthermore, the Protekt Aire 9900 comes with additional safety features such as audio/visual alarms for power outage or low pressures. The internal memory retains current settings during power outages, and a lockout key prevents tampering with patient settings. The mattress system is equipped with a fluid-resistant, anti-microbial/anti-bacterial nylon top cover that adds a layer of comfort and hygiene. With optional air bolsters available in various widths (42”, 48”, 54”, and 60”), and a weight capacity of 1,000 lbs, this mattress system ensures versatility and durability. Backed by a 2-year non-prorated warranty, the Protekt Aire 9900 Mattress System is a reliable and comprehensive solution for patient care.

Documents

Specifications

Pump Dimensions (in.) 15.7(W) x 6.8(D) x 10.8(H)
Pump Weight 14.3 lbs.
Alternate Cycle Time (minutes) 5/10/15/20/25/30
Pulsate Cycle Time (minutes) 1 to 20
Auto-Firm Time (minutes) 20
Pump Output Flowrate (LPM) 1000 (230 V) Note: The flow rate may be varied due to the fluctuation of input voltage.
Pump Output Pressure Range 20 to 46 (±5)
Input Voltage AC 120 V/60 Hz
Weight Capacity 350 to 1,000 lbs.

Warranty

Warranty

2 Year Non-Prorated

Shipping / Returns

This unit is delivered via UPS or FedEx.

The following conditions apply:
  • This item has a 20% Restocking Fee.
  • You are responsible for the cost of return shipping.
  • The product must be new and unused and in the original packaging.
  • All accessories and items that were included in the box must be returned.
  • Items canceled after the product has already shipped will be considered a return.
  • Delivery and service fees are not refundable.
  • Custom-made by the manufacturer to suit your specific needs are non-returnable.
  • An RA (Return Authorization) from Top Mobility must be requested within 15 days of delivery.
  • The item must be shipped back to the address noted on the RA within 15 days.
  • Once approved, your refund, minus any restocking and freight fees, will be issued to your original form of payment.

  • If you have questions about this item please call a Top Mobility Customer Service Expert at 1-888-364-3813.
    Protekt Aire 9900 "True" Low Air Loss Bariatric Mattress System with Alternating Pressure and Pulsation

    $3,350.00 USD